4WPB100, 4WPB1K PRT Bridge
Terminal Input Modules
Revision: 12/06
Copyright © 1996-2006
Campbell Scientific, Inc.
H
L
AG
H
L
AG
H
L
G
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - Terminal Input Modules

4WPB100, 4WPB1K PRT BridgeTerminal Input ModulesRevision: 12/06Copyright © 1996-2006Campbell Scientific, Inc.HLAGHLAGHLG

Pagina 2 - Warranty and Assistance

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 6 4.3 CR7 1: Full Bridge w/mv Excit (P9) 1: 1 Reps 2: 3 ± 15 mV Slow Range 3: 3 ± 1

Pagina 3

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 7 4.5 CR1000 'CR1000 Series Datalogger Public Rs_R0, Temp_C DataTable (Hourly,True,-1) Data

Pagina 4

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 8 The RTD Instruction (16) computes the temperature (°C) for a DIN 43760 standard PRT from the ratio

Pagina 5

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 9 With the PRT at 0 °C, Rs=Ro. Thus, the above result becomes Ro/Rf, the reciprocal of the multipli

Pagina 6 - 3. Wiring

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 10 This is a blank page.

Pagina 8

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Pagina 9 - 4.2 21X

Warranty and Assistance The 4WPB100, 4WPB1K PRT BRIDGE TERMINAL INPUT MOUDLES are warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in ma

Pagina 10 - 4.4 CR9000X

i 4WPB100, 4WPB1K Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookm

Pagina 11 - 4.5 CR1000

This is a blank page.

Pagina 12 - 5.2 Calibrating a PRT

1 4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 1. Function Terminal input modules connect directly to the datalogger's input terminals to p

Pagina 13

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 2 GNDHILORfGNDHLRf = 100 , 1kVx10k5%RsHILO0.01% FIGURE 2-1. Circuit Schematic 3. Wiring The Ter

Pagina 14 - This is a blank page

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 3 TABLE 3-1. 4WPB100/4WPB1K Connections to Campbell Scientific Dataloggers Function Label/Le

Pagina 15

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 4 650 329.51 753 1507 700 345.13 720 1441 750 360.47 691 1382 800 375.51 664 1328 850 390.26

Pagina 16

4WPB100, 4WPB1K PRT Bridge Terminal Input Modules 5 4.1 CR10(X) 01: Full Bridge w/mv Excit (P9) 1: 1 Reps 2: 23 ±25 mV 60 Hz Rejection Ex Rang