Section 8. Operation
360
Figure 114: DevConfig Deployment | Advanced tab
Table 86. PakBus-LAN Example Datalogger-Communications Settings
Software Device Configuration Utility (DevConfig)
Tab
Deployment
Sub-Tab
Datalogger ComPort Settings
Advanced
Setting
PakBus Adr COM1 COM2
Is Router
Sub-Setting
Baud Rate
Neighbors
1
Baud Rate
Neighbors
1
Datalogger Begin: End: Begin: End:
CR1000_1 1 115.2K Fixed 2 2 115.2K Fixed 3 4
Yes
CR1000_2 2 115.2K Fixed 1 1 Disabled
No
CR1000_3 3 115.2K Fixed 1 1 115.2K Fixed 4 4
Yes
CR1000_4 4 115.2K Fixed 3 3 Disabled
No
1
Setup can be simplified by setting all neighbor lists to Begin: 1 End: 4.