SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES
8-14
20: Covariance/Correlation (P62)
1: 5 No. of Input Locations
2: 5 No. of Means
3: 5 No. of Variances
4: 0 No. of Std. Dev.
5: 4 No. of Covariance
6: 2 No. of Correlations
7: 300 Samples per Average
8: 1 First Sample Loc [ W1 ]
9: 20 Loc [ MEAN_W1 ]
21: Covariance/Correlation (P62)
1: 5 No. of Input Locations
2: 5 No. of Means
3: 5 No. of Variances
4: 0 No. of Std. Dev.
5: 9 No. of Covariance
6: 2 No. of Correlations
7: 300 Samples per Average
8: 11 First Sample Loc [ W2_i ]
9: 36 Loc [ mean_W2 ]
22: Real Time (P77)
1: 0110 Day,Hour/Minute
23: Sample (P70)
1: 35 Reps
2: 20 Loc [ mean_W1 ]
TABLE 8.10-4. Thirty Minute Output From Example
01 119 02 DAY 03 HRMIN 04 M(W1) 05 M(U1) 06 M(V1) 07 M(Ta1) 08 M(e1)
09 V(W1) 10 V(U1) 11 V(V1) 12 V(Ta1) 13 V(e1) 14 CV(W1,U1) 15 CV(W1,V1) 16 CV(W1,Ta1)
17 CV(W1,e1) 18 CR(W1,U1) 19 CR(W1,V1) 20 M(W2) 21 M(U2) 22 M(V2) 23 M(Ta2) 24 M(e2)
25 V(W2) 26 V(U2) 27 V(V2) 28 V(Ta2) 29 V(e2) 30 CV(W2,U2) 31 CV(W2,V2) 32 CV(W2,Ta2)
33 CV(W2,e2) 34 CV(U2,V2) 35 CV(U2,Ta2) 36 CV(U2,e2) 37 CV(V2,Ta2) 38 CV(V2,e2)