Campbell-scientific 092 Barometric Pressure Sensor Manuale Utente

Navigare online o scaricare Manuale Utente per Strumenti di misura Campbell-scientific 092 Barometric Pressure Sensor. Campbell Scientific 092 Barometric Pressure Sensor User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 24
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Model 092
Barometric Pressure Sensor
Revision: 8/12
Copyright © 2012
Campbell Scientific, Inc.
Vedere la pagina 0
1 2 3 4 5 6 ... 23 24

Sommario

Pagina 1 - Barometric Pressure Sensor

Model 092 Barometric Pressure SensorRevision: 8/12 Copyright © 2012Campbell Scientific, Inc.

Pagina 2

Model 092 Barometric Pressure Sensor 3. Select 092 Barometric Pressure Sensor and click the right arrow in the middle of the page to add it to the li

Pagina 3 - Warranty

Model 092 Barometric Pressure Sensor 5. Sensor connections to the CR1000 datalogger are shown in the Wiring tab. 6. Select the desired output data

Pagina 4 - Assistance

Model 092 Barometric Pressure Sensor 5. Overview The 092 ships from Campbell Scientific pre-wired for analog output with the following settings: • A

Pagina 5 - Table of Contents

Model 092 Barometric Pressure Sensor 6. Specifications Features: • The following 092 barometer settings are configurable: o measurement range o da

Pagina 6

Model 092 Barometric Pressure Sensor southern hemisphere. This orientation will shield the polycarbonate sensor housing from most direct sunlight. 7.

Pagina 7 - 4. Quickstart

Model 092 Barometric Pressure Sensor 'Main Program BeginProg 'Main Scan Scan(5,Sec,1,0) 'Default Datalogger Battery Voltage measu

Pagina 8

Model 092 Barometric Pressure Sensor 10

Pagina 9

Appendix A. Analog Output Configurations The 092 ships from Campbell Scientific pre-wired and pre-configured for analog output with the following se

Pagina 10

Appendix A. Analog Output Configurations A-2 TABLE A-2. Dip Switches SW2: Analog Output Pressure Range Settings RANGE SELECTION SWITCH SETTINGS mb

Pagina 11

Appendix B. Wiring The 092 ships from Campbell Scientific pre-wired for analog output. Internal cable connections are shown in FIGURE B-1. FIGURE

Pagina 13 - 7. Installation

Appendix B. Wiring B-2

Pagina 14 - 7.3 Programming

Appendix C. CE Certification C-1

Pagina 15 - 8. Maintenance

Appendix C. CE Certification C-2

Pagina 17 - Appendix A. Analog Output

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Pagina 18

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Pagina 19 - Appendix B. Wiring

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Pagina 20

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Pagina 21

Table of Contents ii Tables 7-1. Connecting the 092 to Campbell Scientific Dataloggers... 8 A-1. Dip Switches SW1: Analog Output V

Pagina 22

Model 092 Barometric Pressure Sensor 1. Introduction The Model 092 Barometric Pressure Sensor is designed to measure ambient atmospheric pressure an

Pagina 23

Model 092 Barometric Pressure Sensor FIGURE 4-1. 092 installed on a vertical mast Individual wire leads connect to the CR1000 datalogger as shown in

Pagina 24

Model 092 Barometric Pressure Sensor 4.2 Programming with Short Cut Short Cut Program Generator for Windows can be used to program the CR1000 datalog

Commenti su questo manuale

Nessun commento