Installing EnviroSCAN, EnviroSMART & Diviner 2000 access tubes
© Sentek Pty Ltd Page 25
20. When all pins are removed, carefully lift the tripod straight upward and off the access tube.
21. Try twisting and moving the tube backwards and forwards while examining the surface soil
surrounding the access tube. The tube should not move and there should be no visible air
gaps.
22. If there is an air gap, retrieve the access tube and start the installation process again at a
site that is at least one metre away from the failed installation.
Note: Clean the tools and return them to the case after use to ensure they are not
lost or damaged.
Vedere la pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 56 57