NR-LITE2 Net Radiometer
6.1 Spectral
Spectral range: 0.2 to 100 μm
Detector type: Thermopile
Detector protection: PTFE coating
Detector profile: Conical
6.2 Directional
Directional error
(0° to 60°C at 1000 W m
-2
): <30 W m
-2
Sensor asymmetry: ±5% typical, (±10% worst case)
6.3 Mechanical
Housing material: Anodized aluminum
Cable material: Polyurethane
Weight: 200 g
Cable length: 15 m (can be extended up to 100 m)
Physical dimensions (FIGURE 6-1)
Sensor: 8.0 cm (3.1 in) diameter
Support arm: 1.6 cm (0.6 in) diameter x 80 cm (31.5 in) L
Weight: 635 g (23 oz)
Bird repelling stic
k
16 x 800 Support Arm
80
Bubble level indicator
Ad
j
ustable mountin
g
arm
Support arm
FIGURE 6-1. NR-LITE2’s components and dimensions (in millimeters)
6.4 Environmental
Working temperature: 30° to +70°C
Temperature dependence: 0.12% per °C