NR-LITE2 Net Radiometer
7. Operation
7.1 Wiring
The NR-LITE2 can be measured with a differential or single-ended channel on
the datalogger; a differential channel is recommended.
FIGURE 7-1 provides the NR-LITE2 wiring. Datalogger connections are
shown in TABLE 7-1 for differential measurements and TABLE 7-2 for
single-ended measurements.
Red Radiation Signal
Blue Signal Reference
Blac
k
Shield
(User supplied jumper wire for differential measurement only)
FIGURE 7-1. NR-LITE2 to datalogger connections
TABLE 7-1. Datalogger Connections for Differential Measurement
Function
Color
CR10X,
CR510,
CR500
CR23X,
21X, CR7
CR800,
CR850,
CR1000,
CR3000,
CR5000,
CR9000(X)
Radiation Signal Red Differential H Differential H Differential H
Signal Reference Blue Differential L Differential L Differential L
Jumper to AG
Shield Black G
13